Testing Capabilities

X-POWER offers an advanced testing infrastructure to characterize high frequency magnetic components at both low power and realistic operation conditions. It is de facto standard equipment for research & development of soft magnetic materials, and complies IEC62044-3 standard.

Advanced High-frequency high-precision Magnetic Component Characterization System

Specifications

  • Frequency: 10Hz to 10MHz
  • Voltage: ±140V / Current  : ±5.2A
  • DC-bias: 30A  / AC ripple:  ±6A 
  • Measurement items:  core loss (Pc,Pcv,Pcm), phase(θ), flux linkage(2φm), apparent power(VA), loss coefficient(tanδ), Inductance(L), Resistance(R), Impedance(|Z|), quality factor(Q), total harmonic distortion(THD), relative amplitude permeability(µa), impedance permeability(µ;z), complex permeability(µ',µ"), magnetic fluxdensity (Bm), magnetic field strength(Hm), coersiveforce(Hc)
  • Operation Harmonics:  Harmonic active power, select calculation order from 2nd order to 100th order
     
Medium-Freq. Medium-Voltage (MFMV) magnetic test system

Specifications

  • Frequency:  1 kHz to 100 kHz
  • Voltage:  400V & 3.3 kV
  • Power range: up to 10 kVA
  • Measurement items: core loss (Pc,Pcv,Pcm), phase(θ), apparent power(VA), Inductance(L), Resistance(R), Impedance(|Z|), quality factor(Q), total harmonic distortion(THD), magnetics total loss
  • Operation waveforms: rectangle

Potential to Research and Industry Service

  • Support research on high-frequency low-voltage magnetics with state-of-the-art characterization setup.
  • Support research on degradation testing of magnetic components to characterize the parameter shifts.
  • Provide application-oriented characterization of magnetic components for industry applications covering wide range of frequency and voltage conditions.